Portland Composite Cement
- 65% < Clinker < 79%
- 21% < Calcined natural pozzolana + Limestone < 35%
- Setting time regulating calcium sulfate
Technical Requirements
Sulfate (SO3) < 3,5%
Chloride (CI) < 0,10%
Initial Setting (min)> 60
Soundness (mm) <10
Compressive Strength Development
Minimum values
2 days: 10,0 MPa
28 days: 42,5 MPa < 28 days< 62,5 MPa
Advantages of concrete produced with CEM II/B-M (Q-L) 42,5 N
- Low hydration heat
- High ultimate strength
- Wide range of usage in moderately aggressive environments.
- High workability Particularly suitable for XC exposure classes.
Recommended Applications
- Ready – Mix Concrete Suitable for the production of all comprehensive strength classes. It gives high performance especially in C20/25 to C40/50.
- Precast Production Suitable for production of masonry blocks and lightweight concrete.
- Road Pavements Suitable for concrete pavements for roads and wearing surfaces
- General Use All kinds of grout mortar, plaster and repair works.
- Mass concrete.
- All kinds of mortar.
Environment, Safety and Storage
- Wear suitable protective clothing, gloves,eye and face protection equipment.
- Lower CO2 emission into the atmosphere
- For detailed safety information, please see Technical Data Sheet, available at www.cimpor.com
Precautions in Application
- Follow the standard minimum cement content and maximum water/cement ratio.
- Provide adequate protection and cure according to correspondent standards.
- Keep framework and scaffolding in place until adequate mechanical strength is obtained.
- Follow the correspondant standard and Specifications for aggressive environments.
Not recommended for:
- Not suitable for ready-mixed concrete productions where early strength is critical.
- Not suitable for concrete production to be poured without any measures under cold weather conditions.